Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Mais filtros










Base de dados
Assunto principal
Intervalo de ano de publicação
1.
Parasit Vectors ; 17(1): 138, 2024 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-38491557

RESUMO

BACKGROUND: The aim of this study was to determine performance indicators of thick blood smears of 50 µl (TBS-50), following the Standards for the Reporting of Diagnostic Accuracy Studies-Bayesian Latent Class Model (STARD-BLCM) guidelines. TBS-50 was compared with two common parasitological techniques-direct examination of 10 µl blood and a leukoconcentration of 5 ml-for the diagnosis of microfilaremic loiasis. METHODS: The study population was recruited among patients of the Department of Parasitology-Mycology-Tropical Medicine over a period of 1 year. Age, sex, symptoms, and eosinophilia variables were recorded from laboratory registers and medical files. Direct examination of 10 µl of blood, TBS-50, and the leukoconcentration technique with 5 ml of blood were performed for each patient. The classical formula and BLCM were used to determine the diagnostic accuracy of the three techniques as well as the prevalence of microfilaremic loiasis. Three models were built within the framework of BLCM-the BLCM model I and alternative models II and III-for sensitivity analysis. RESULTS: In total, 191 patients consented to be included. The direct blood examination and TBS-50 yielded comparable qualitative and quantitative results. Hence, they are reported together. The prevalence of Loa loa microfilaremia was 9.4% (95% CI 5.7-14.5; n = 18/191) with direct blood examination/TBS-50 and 12.6% [8.2-18.1] (n = 24/191) for leukoconcentration. Comparing TBS-50 with the leukoconcentration method using the classical formula, the sensitivity was 75.0% [53.3-90.2], specificity was 100.0% [97.8-100.0], the positive predictive value was 100.0% [81.5-100.0], and the negative predictive value was 96.5% [92.6-98.7]. The prevalence of microfilaremic loiasis was estimated at 9.7% [6.2-13.7] using BLCM model I. The outputs of BLCM model I showed sensitivity of 78.9% [65.3-90.3], specificity of 100.0% [99.3-100.0], a positive predictive value of 99.1% [87.2-100.0], and a negative predictive value of 93.0% [87.3-97.7] for direct blood examination/TBS-50. CONCLUSIONS: TBS-50 demonstrates low sensitivity relative to two other techniques. In one in five cases, the result will be falsely declared negative using these methods. However, this method can be deployed with limited funds.


Assuntos
Loíase , Animais , Humanos , Loíase/diagnóstico , Loíase/epidemiologia , Gabão/epidemiologia , Teorema de Bayes , Análise de Classes Latentes , Prevalência , Loa
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...